Rising compute densities expose limits of the ubiquitous PUE metric and force a rethink of data-centre sustainability: the report urges compute-focused efficiency metrics and highlights trade-offs between on-site cooling water use and upstream water/energy impacts while recommending circularity measures across design, materials and operations.

Circular Economy Synergies and Trade-offs in Data Centres
Vlad C. Coroamă, Oana Dumbravă · August 05, 2026
arxiv descriptive low evidence 6/10 relevance Full text usable extracted full text Source PDF

Structured author observations

Linked only from stored provider relations; the raw author line above is never matched by name.

Arxiv

Latest observation:

  1. Vlad C. Coroamă unresolved corpus identity
  2. Oana Dumbravă unresolved corpus identity

Semantic Scholar

Latest observation:

  1. Vlad C. Coroamă provider ID
  2. O. Dumbrava provider ID
This Swiss federal report examines data-centre sustainability from a circular-economy perspective, critiques the PUE metric, proposes a trio of energy metrics (compute efficiency, transformation efficiency, cooling overhead), and maps trade-offs across energy, water, waste-heat reuse, materials, and grid interactions.

Citation observations

Cumulative provider counts captured on specific dates; providers are never combined.

This report analyses data centre (DC) sustainability and circularity, revealing existing synergies and trade-offs: The PUE is too coarse, mixing cooling and power provisioning. It wrongly attributes server fan consumption and transformation losses to IT energy. It does not measure compute but infrastructure efficiency, which is already outstanding. Compute energy, however, is exploding. Better energy metrics for DCs would thus cover i) compute efficiency, ii) transformation efficiency, and iii) cooling overhead. Trade-offs exist between cooling energy and water as well as on-site and upstream water: Consuming water on-site lowers the cooling energy, which also lowers the water consumed upstream in power generation. For 'wet' electricity, there is little competition: It is worth spending more on-site energy to save both electricity and related upstream water. For 'dry' electricity, there is a trade-off. Waste heat recovery brings energy circularity but has limited uses and is not the same energy quality, a fact not reflected by current metrics. A better metric would consider the avoided energy through heat recovery instead of the amount recovered. Material circularity can be achieved by interpreting the 9R framework in the context of DCs. Circularity-enhancing measures can be categorised into product design, process design and business models, choice of materials, and operating conditions. Together, they have effects across all circularity levels. The relation between DCs and the power grid is complex. Modern DCs present new challenges for the grid. Mitigation includes battery storage and onsite generation. These measures have, in turn, further consequences, both beneficial and detrimental. They can offer grid flexibility as well as innovations in the field of energy. But they also bring noise, pollution, and GHGs, and compete with the energy sector for resources.

Summary

Main Finding

The report finds that continued data-centre (DC) growth creates both circular-economy opportunities and multi-dimensional trade-offs. Key technical and metric reforms are needed: PUE is a flawed, coarse metric and should be complemented (or partially replaced) with a small set of disjoint metrics that separately capture (i) compute efficiency, (ii) power-transformation efficiency (including PSU losses), and (iii) cooling overhead. Energy–water trade-offs in cooling, limited and location-sensitive value of waste-heat recovery, and large knowledge gaps in microelectronics production (especially mineral refining) mean that circularity measures (design, process, materials, business models, and operation) and lifespan extension are robust, economically aligned levers — but their net benefits depend strongly on local electricity-water regimes, grid interactions, and supply-chain constraints.

Key Points

  • Limitations of PUE

    • PUE is relative and infrastructure-focused (cooling + power provisioning), not a measure of compute energy or absolute consumption.
    • It misattributes server-fan and PSU conversion losses to “IT” energy and therefore hides important transformation inefficiencies.
    • Infrastructure efficiency (PUE improvements) is largely saturated; future gains from compute-side efficiency are far more consequential.
  • Recommended energy metrics

    • Propose three complementary metrics: compute efficiency (work per energy, workload-agnostic), transformation efficiency (end-to-end power provisioning losses, including PSUs), and cooling overhead (energy for cooling/auxiliary systems).
    • The transition to DC distribution with higher voltages and DC architectures is an opportunity to build these metrics into design and reporting.
  • Power provisioning trends

    • Shift toward direct current and higher-voltage internal distribution to reduce conversion losses.
    • A comprehensive metric for power provisioning should be disaggregated from cooling and include PSU and distribution losses.
  • Water and cooling

    • On-site water use depends strongly on cooling technology: cooling towers and waterside economizers are high-water; dry coolers and airside economizers are low-water but often use adiabatic assistance intermittently (so use some water).
    • Indirect (upstream) water use is dominated by electricity generation (notably behind-the-dam evaporation for hydropower).
    • Trade-offs: water-intensive cooling reduces cooling energy and thus upstream water embodied in electricity; which option is preferable depends on the “wetness” of the local electricity mix.
  • Waste heat reuse

    • Waste-heat recovery can increase energy circularity but is constrained: heat quality is limited, applications are location-dependent (proximity to heat demand), and trade-offs exist between minimizing cooling energy (often located in cold, remote sites) and maximizing reuse (near population centres).
    • Metrics should focus on avoided energy (what the recovered heat substitutes) rather than only quantity of heat recovered.
  • Production impacts and circularity of hardware

    • The environmental impacts of microelectronics are poorly quantified, especially mineral refining/purification.
    • Extending hardware lifespans is consistently beneficial for sustainability and often aligns with CapEx incentives.
    • Circularity levers span product design, process & business models, material choices, and operations; general frameworks (e.g., 9R) can be applied to DCs and component supply chains.
  • Grid interactions and system-level trade-offs

    • Modern DCs present large, concentrated, and rapidly ramping loads (AI workloads accentuate ramps).
    • Mitigation strategies—workload shifting, on-site generation, battery storage—provide grid flexibility but create trade-offs: local pollution/noise, extra embodied emissions and materials competition (batteries, generators), and potential distortions of system-level emissions.
    • DCs can provide valuable flexibility services but this must be evaluated against resource competition and externalities.

Data & Methods

  • Type of study: Technology- and policy-oriented synthesis report combining literature review, engineering analysis, conceptual metric design, and trade-off assessment. It is not primarily an original empirical LCA dataset.
  • Sources: Academic literature, engineering/industry technical documents on DC topology, cooling technologies, power distribution, water-use metrics (WUE), PSU and distribution efficiency studies, and lifecycle insights on microelectronics production. (Report: Swiss Federal Office of Energy, Final report 21 April 2026; authors Vlad C. Coroamă & Oana Dumbravă.)
  • Methods used:
    • Conceptual analysis of existing metrics (PUE, WUE) and identification of conceptual biases and blind spots.
    • Comparative assessment of cooling technologies (dry coolers, air/cooled chillers, water-cooled chillers, waterside/airside economizers, adiabatic assistance) for energy and water impacts.
    • Thermodynamic and electrical-transmission reasoning to evaluate benefits of DC power-distribution changes (higher voltage, DC).
    • Lifecycle and supply-chain discussion for microelectronics, highlighting knowledge gaps (mineral refining).
    • Application of circular-economy frameworks (e.g., 9R) to identify intervention points across product, process, material, and operating domains.
  • Limitations noted by authors:
    • Sparse, uncertain empirical data on microelectronics refining impacts.
    • Practical difficulties in defining a universally applicable compute-efficiency metric across heterogeneous workloads.
    • Context dependence of cooling/water trade-offs (region-specific power mix and water availability).

Implications for AI Economics

  • Need for a compute-efficiency metric tailored to AI

    • Economic models and deployments that price and optimize AI workloads should not rely on PUE. They need a workload-agnostic compute-efficiency metric (work per joule) that captures heterogeneous AI model types, inference vs. training, and amortized efficiency across accelerators and software stacks.
    • Such a metric would enable better comparisons across providers, more accurate cost-of-compute signals, and improved incentives for algorithmic and hardware efficiency.
  • Cost and investment signals

    • Transition to higher-voltage/DC power distribution and liquid cooling requires upfront capital but reduces transformation losses and operating costs. AI data-centre investors should account for trade-offs in CapEx vs. long-run OpEx and for changes in accounting of transformation efficiency in procurement decisions.
    • Water-related costs and constraints create location-dependent operating costs for AI workloads. AI economists should internalize regional electricity “wetness” and local water scarcity into location choices and long-run cost models.
  • Valuing flexibility and grid interactions

    • AI workloads can be a flexible grid resource (demand response, temporal shifting of non-urgent training), which has economic value. Quantifying this value requires modeling revenue streams from ancillary services and potential savings from avoided grid investments.
    • Conversely, on-site batteries and generation impose opportunity costs (materials, embodied emissions) and may compete with other sectors’ flexibility needs; economic analyses should include these resource-competition externalities.
  • Supply-chain and scarcity risks

    • Poorly understood environmental and material impacts in microelectronics (refining, critical minerals) imply supply-risk premiums. AI economics must factor potential scarcity, geopolitical concentration, and cost volatility of advanced chips and battery/energy materials into total cost of ownership and long-run AI scaling scenarios.
  • Circularity and lifespan economics

    • Extending hardware lifetimes and shifting business models (e.g., modular repairable designs, leasing, secondary markets) often yield both sustainability and economic benefits (lower lifetime cost per unit of useful compute). AI firms should include lifespan-extension and circular procurement in capital planning.
    • Software and workload optimization (model compression, sparsity, efficient pipelines) produce outsized returns as infrastructure efficiency gains are near-saturated.
  • Carbon/water accounting and policy

    • Carbon and environmental accounting for AI should not use PUE alone. More disaggregated metrics (compute efficiency, transformation losses, cooling overhead) and upstream water-embodied indicators are needed to accurately price externalities (carbon taxes, water pricing, regulation).
    • Policy instruments that reward avoided energy (e.g., via heat reuse credits calibrated to avoided fuel/energy) and that account for local water impacts will alter optimal siting and operational strategies for AI workloads.
  • Heat reuse and demand clustering

    • Waste-heat monetization is location- and temperature-quality dependent. AI economic strategies that rely on heat valorization should evaluate whether proximity to heat demand and the quality/temperature of exhaust make reuse economically material or only marginal.

Overall, for AI economics, the report implies a shift from infrastructure-centric KPIs (PUE) toward metrics and economic models that place compute efficiency, power transformation losses, water/energy trade-offs, and lifecycle/resource constraints at the centre of cost and policy analysis.

Assessment

Paper Typedescriptive Evidence Strengthlow — The document is a government technical/policy report synthesizing engineering literature, metrics, and trade-off analyses rather than presenting new causal empirical tests; claims are largely conceptual, descriptive, and supported by technical reasoning and secondary sources rather than rigorous causal identification. Methods Rigormedium — The report demonstrates domain expertise, systematic discussion of metrics and technologies, and draws on existing technical data and literature, but it lacks formal empirical identification, controlled comparisons, or statistical causal analysis. SampleA synthesis of technical literature, industry data, engineering metrics, and policy analyses on data centres (energy use, cooling technologies, power provisioning, water footprint, waste heat reuse, and microelectronics production); no single primary causal dataset or randomized intervention is reported in the supplied text. Themesinnovation adoption GeneralizabilityFocused on data centres and their infrastructure; does not directly generalize to broader AI economic outcomes (e.g., labor, wages, firm productivity)., Technical recommendations (cooling, DC power provisioning) depend on local climate, grid mix, and regulatory context — results may vary by geography., Some findings depend on electricity generation mix (hydro vs thermal), so trade-offs between on-site and upstream water/energy are context-specific., Production-impact discussion of microelectronics is high-level; lacks comprehensive lifecycle data across global supply chains.

Claims (12)

ClaimDirectionOutcomeConfidence & EvidenceDetails
The PUE metric does not indicate a data centre's total energy consumption because it is a relative measure. Organizational Efficiency negative Validity and informativeness of data-centre energy-efficiency measurement
Reading fidelity high
Study strength medium
not reported
0.18
PUE is too coarse because it combines cooling and power-provisioning infrastructure into a single metric, mixing their individual efficiencies. Organizational Efficiency negative Diagnostic resolution of energy-efficiency measurement
Reading fidelity high
Study strength medium
not reported
0.18
PUE measures infrastructure efficiency rather than compute efficiency. Organizational Efficiency negative Compute-efficiency measurement
Reading fidelity high
Study strength medium
not reported
0.18
The report argues that data centres need a compute-efficiency metric that can compare heterogeneous computing workloads because compute energy consumption is increasing rapidly. Organizational Efficiency negative Energy efficiency of computing workloads
Reading fidelity high
Study strength medium
not reported
0.18
The report recommends a set of data-centre energy metrics comprising compute efficiency, transformation efficiency, and cooling overhead. Organizational Efficiency positive Comprehensiveness and interpretability of data-centre energy metrics
Reading fidelity high
Study strength low
not reported
0.09
On-site water consumption varies substantially by cooling technology: waterside economisers and water-cooled chillers have high water consumption, whereas dry coolers, air-cooled chillers, and airside economisers generally do not, although adiabatic support can make the latter intermittently water-consuming. Organizational Efficiency mixed On-site water consumption associated with cooling
Reading fidelity high
Study strength medium
not reported
0.18
Water-intensive cooling generally reduces cooling energy use and therefore can also reduce upstream water consumption associated with electricity generation. Organizational Efficiency mixed Combined cooling energy use and upstream water consumption
Reading fidelity high
Study strength medium
not reported
0.18
The energy-water trade-off in data-centre cooling is more pronounced when electricity production is relatively water-dry; with water-intensive electricity production, using additional on-site water is generally more worthwhile for saving electricity and upstream water. Organizational Efficiency mixed Trade-off between on-site and upstream water consumption and energy use
Reading fidelity high
Study strength low
not reported
0.09
Waste-heat recovery from data centres involves a trade-off between maximising heat reuse near populated areas and minimising energy consumption in colder, remote locations. Organizational Efficiency mixed Waste-heat reuse and associated energy consumption
Reading fidelity high
Study strength medium
not reported
0.18
The sustainability impacts of microelectronics production are poorly understood, with mineral refining and purification identified as the least-understood of the mining, refining, and fabrication phases. Ai Safety And Ethics negative Knowledge of production-related sustainability impacts
Reading fidelity high
Study strength low
not reported
0.09
The report states that extending the lifespan of data-centre IT components is beneficial for material circularity. Organizational Efficiency positive Material circularity and environmental burden of data-centre hardware
Reading fidelity high
Study strength low
not reported
0.09
Data-centre mitigation measures such as workload shifting, battery storage, and on-site generation can provide grid flexibility and stimulate energy innovation, but can also cause noise, pollution, greenhouse-gas emissions, and competition for energy-sector resources. Organizational Efficiency mixed Grid flexibility and adverse externalities associated with data-centre operation
Reading fidelity high
Study strength medium
not reported
0.18

Notes